HARDNESS TESTER
|
|
|
|
BRINELL HARDNESS TESTER (SLE-550)
Test Force |
: 1839N (187.5kgf), 2452N (250kgf), 7355N (750kgf), 9807N (1000kgf), 29420N (3000kgf) |
| Indenter Ball Diameter |
: 2.5mm, 5mm and 10mm |
| Test Force Dwell Time |
: 6~99s adjustable |
| Testing Range |
: 8~650HBW |
| Horizontal Testing Space |
: Max.230mm (9'') |
| Vertical Testing Space |
: Max.120mm (4.7'') |
| Power Supply |
: 220V/110V, 50~60Hz, 2A |
| Net Weight |
: 218 kg |
| Dimesions |
: Max.730 x 230 x 890mm |
top
|
|
DIGITAL MICRO HARDNESS TESTER
| Load Test |
: 0.098,0.246,0.49,0.98,1.96,2.94,4.90,9.80N(10-1000kgf) |
| Loading Mechanism |
: Automatic loading and releasing method |
Magnification of Scope |
: Measuring: 400x (Object lens 40x, Eyepiece 10x)
Observation: 100x (Object lens 10x, Eyepiece 10x) |
| Load Holding Time |
: 5~60sec |
Measuring Microscope |
: Mechanical Digital Max. measuring length: 150 micro m Min. measuring unit: 0.0625 micro m |
| Max. Height of Specimen |
: Approx 65mm |
| Max. Depth of Specimen |
: Approx 85mm |
Micro Test Table |
: Dimension: 100 x 100mm Max.movement: 25mm in X&Y axis Min. micro graduation: 1/100mm |
| Digital Data Display |
: (0~250)HV |
| Automatic Recorder |
: Printer |
| Photographic Device |
: Possible to install at any time |
| Dimension of Tester |
: W290 x D405 x M480mm |
| Weight of Tester |
: 25kg |
| Power Supply |
: AC220V/110Vą10% 50Hz/60Hz |
top
|
|
DIGITAL ROCKWELL HARDNESS TESTER (SLE-550)
| Pre Load |
: 98.1N (10kgf) |
| Total Load |
: 588.4N (60kgf), 980.7N (100kgf), 147N (150kgf) |
| Rockwell Scales |
: 1~100HRA, 0~130 HRB, 0~100HRC |
| Testing Resolution |
: 0.1Rockwell unit |
Working Method |
: Auto loading of main test force, auto hold and digital display of results |
| Vertical Testing Space |
: 200 mm |
Horizontal Space between indenter axis and front wall |
: 160 mm |
| Dimesions |
: 580x270x740mm |
| Weight |
: 100 kg |
top
|
|
VICKER HARDNESS TESTER (SLE-30)
Test Load |
: 19.6N(2kgf), 29.4N(5kgf), 98.0N(10kgf), 196N(20kgf), 294N(30kgf), 490N(50.0kgf) |
| Hardness Value Symbol |
: HV2, HV3, HV5, HV10, HV20, HV30 |
| Error range in display |
: +/- 3.0% |
Hardness value range in measure |
: 10HV2~2500HV30~2.0% |
Pressure loading & unloading method |
: Automatic |
| Magnification of microscope |
: 100X |
| Pressure holding time |
: 0~30s (5 second as input increment)micro m |
| Minimum measurable unit |
: 1 micro m |
| Maximum height of sample |
: 150 mm |
Distance from indenter's center to outer wall |
: 130 mm |
| Main unit weight |
: Approx.38Kg |
| Power source |
: AC220V/110V 50Hz/60Hz |
| Machine size(L x W x H) |
: Machine size(L x W x H) |
top
|
|
|
|
|