Introduction
Suspended Particles upto 100 microns have emerged as the most critical among all
the criteria air pollutants & is caused by number of sources like:
- Large, medium & small-scale industries
- Road dust construction activities, house hold fuel cooking, waste burning, vechicular emissions etc.
In order to control the pollution, it is necessary to periodically
monitor the air to determine the extent of pollution and to identify the
source of emission SLE-HUS123 is designed to meet these needs. This model
confirm to guidelines of Central Pollution Control Board.
Principle
The high volume air sampler collects suspended particulates on large filter paper.
The name high volume is appropriate because the sampling flow rate has a high level of
20 to 60standard cubic feet per minute (SCFM). Because of the high flow rate, large
quantities of particles ranging from 0.1 to 1 gram are collected over a typical
24-hour sampling period. This facilitates gravimetric and chemical analysis and
is the advantage hi vol samplers have over other air sampling methods.
Specifications
| Model |
: SLE-HVS123 |
| Flow Rate |
: 0.8 to 1.8 m3/min |
Particle Size |
: Down to 1.6 micron depending upon Filter used |
Blower |
: Continuous duty blower with brushless motor |
| Recommended filter |
: GF/A (8” X 10”) for common use, EPM 2000 for Special Research or equivalent |
| Time Record |
: 0 to 99999.99 hrs. Time totalizer records the running time in hours |
Timer |
: 24 Hr programmable timer, number of required intervals can be programmed |
| Power requirement |
: 220 Volts, Single phase AC |
Features
Brushless Blower.
Low running cost.
Low noise operation.
Controlled flow.
Light Weight & Small in Size.
Drain plug for manometer.
Back to Environment Equipments